Specifications
CONTROL PERFORMANCE
Accuracy: 0.5% of proportioning valve range
Repeatability: 0.2% of proportioning valve range
Linearity: 0.2% of proportioning valve range

HYDRAULIC FLUID
Maximum Hydraulic Pressures:
Inlet (from hydraulic power unit), psi: Standard-6000, Optional-11,000
Outlet (to test article), psi: Standard-5000, Optional-10,000
Return (to hydraulic power unit), psi: Standard-100 , Optional-100
Minimum Supply Pressure: 500 psi greater than the maximum anticipated outlet pressure.

Specification: MIL-H-5606 ("Red Oil"). Consult Edison for application of other petroleum or water based fluids.

Filtration: 3 micron (nominal) is desirable. 10 micron (nominal) or better is required.

Temperature: 100 F 10 degrees F is optimum. 125 F or lower is required.

Flow: Depends on pressures, cycling rate, number of channels, and other factors. Call Edison for assistance.

STANDARD HYDRAULIC CONNECTIONS
Inlet and Return: 1-inch 37 Male Flared Tube (MS/SAE-16)
Outlet: 1/2-inch 37 Female Flared Tube (MS/SAE-8)

ELECTRICAL POWER REQUIREMENTS
Standard:115 VAC, 60 Hz, 5 A

DIMENSIONS
Weight: 240 lbs.
Shipping weight, including crate: 360 lbs.